The Tristar VS would be a good choice and easy to plumb, since its the same pump. Hello, Perflex filters are particularly known (to me anyway) for building up oily deposits on the fingers or flex tubes, and clogging up quickly. You could provide a kind of tabletop shade to the motor, but dont enclose it and restrict air flow. Checked pump later, not running with message Drive error, heatsync overheated. Hi Yolanda, also a great question first plug something else like a hair dryer or lamp into the outlet, to be sure its supplying 115V properly (or use a test meter). If the wiring is Ok and the error persists, replace the sensor. The pipe connection became disconnected and flooded the pool house overnight after initial opening and start up The pump stopped priming and allowed water to just flow through but not pressurize the closed filter basket part that is right before the pumpso it looks like a waterfall in the basket flowing from the pipe coming from the pool to the lower end going into the filter. Hi John, that is going to be either a cavitation noise, where the pump is starved for water, or if this noise is new, it would likely be the front and/or rear motor shaft bearings wearing out. I replaced the pump thinking it was bad. A bad shaft seal or loose pipe is likely the cause of your leaky pump. With your timeclock or switch turned on, you should see about 220V, give or take 10%. The motor had stopped when I checked in morning. HI Alberto, if a motor is overheating, it normally takes about 15-20 minutes, and then the thermal overload switch, located in the rear of the motor, will trip, shutting off the pump for about 15-20 minutes, until it is cool enough to start again, on its own. See below for more detail. Or use this Pump Cord. For a DE filter, pull out the grids and clean them off. Any suggestions what it could be. Is this normal or is there a malfunction? I can turn the temperature up but not down. I did notice the on/off switch was mushy moving from the on and off positions. Finally, in cases of very hard water, some of your sand bed may have calcified, and need to be replaced. If assumed to be the capacitor, get the MFD number printed on it, and find an exact replacement capacitor on our site, or from a local electric motor shop. I have a Hayward Super II pump. },
The 1.5 hp pump was so strong you couldnt stand in front of the single return, which is why I used smaller pump. Then we hear a click and the whole display goes blank. Some times it has overheated, it did re start, but I want to make sure that the motor is supposed to run continuously. Any ideas why this would happen? We knows its not electrical. If flame is sensed with the gas valve off the control will go into lockout. Our pump wont start at all after opening the pool. dr myers ultrasound. Third possibility is just that the pump capacitor is bad, if the motor wont turn over, wont spin. Hi Dave, check that the centrifugal switch is screwed on tightly to the end of the motor shaft. This could drain the pool down to the skimmer, or possibly much lower in some cases, so keep a close eye on any leak and look for signs of worsening. ring wont spin loosely around but it didnt seem to help. The board wasnt showing anything. Thanks. One of the tads were not in the slot. If you have a power meter you can turn clock on and see if power is getting to the motor 110-120V. Inspect the following areas: If you see air bubbles coming from the return fittings on the pump, there may be an air leak on the suction side. "primaryImageOfPage": {
Old bronze pool pumps, like Sta-Rite and Anthony, that use Key Shaft motors with stub shafts need to be shimmed properly. The arrow at the top of the hex nut points in the direction of the water flow. Sun was beating on it. Big mistake! This is weird, no? Pumps normal pressure and pulls enough volume to keep bakery full. When I finally turned it off again it would not come back on. Could be one of these. Hi Peter, I think you might be jumping the wrong terminals? Whats the problem. We purchased a Hayward D.E Filter last summer. Hi George, that is a strange one, because you dont backwash, yet pressure returns to normal, just by shutting pump off for a minute, then restarting? However, no matter what. Use a Drain King to pressurize the pipe backwards, to remove such clogs. Hi Minglin, open up the pump lid, and remove the basket and check if anything is obstructing the impeller, like grass, gravel, seeds, etc. the loosed its prime again. Check the usual spots for air coming into the pump, 1) the threaded pipe coming into the pump (did you use thread sealant? A wire connected to the terminal board may be loose or burnt. Cavitation refers to a pump being starved for water, and as you describe the water level in the pump basket is low, but also the pump makes a grinding noise, like its gargling rocks. The mechanical shaft seal sits behind the impeller, and prevent water from leaking out along the motor shaft. A longstanding legal battle over control of the old Apex Department Store properties in Pawtucket appears to be headed.. Apex Legal Funding is a lawsuit financing company that provides pre settlement funding and post settlement funding to plaintiffs. They dont typically make noise for long either, because at 3400 RPM, if the impeller is hitting something, it will quickly wear it down. Has more of an impeller type sound. Also possible that the rubber is damaged, inspect closely for signs of wear while cleaning it. If the filter was a problem, you may notice higher than normal filter pressure (compared to the old pump). Pump does not overheat or shut off or anything and continues to circulate the water normally, just making a lot of noise, so I have not been running it. The control panel says that theres a driver error. Next step would be to remove the cover and put your leads on the terminal board, right where each wire connects. Buen suerte! Also check that the stationary switch (6 oclock) and the centrifugal switch (dead center) are not loose or misaligned. Motors that are reversible always ship from the factory at 230V, and need to be manually switched to accept 115V. Turn on heater and see if you can narrow down the noise. The sound you reference pumping rocks sounds like a pump that is cavitating, or starved for water. I dont want to pay someone to come out & charge me more for not knowing what Im doing. If you have trouble getting past this, an electrician may be a good call to make. Just replaced the upper lid on my Vari-flow and spider gasket, also changed out 300 lbs filter sand. Just got it a couple of weeks ago. Second possibility is the pump is too high above water level. Heaters often normally make such sounds, could also be debris laying on top of the burners. Im wondering how to fix this problem and/or if a new pump is needed. I call that surging and its commonly caused by an air leak around the pump, either a loose pump lid, bad o-ring or loose drain plug or loose pipe coming into the pump. Only get big time cavitation and the basket empties about half. Then tighten the pump lid very tight. Tested the switch on and off and it works as expected. So, when a pump is surging or pulsing, and not getting up to full head it is either starved for water, because of closed incoming valves, or too big of a pump for too small inlet pipes or because of air being pulled into the pump from air leaks or low water level in pool or from some obstruction in the lines, pipes or valves, a clog or something broken off I have found a Drain King useful in diagnosing such things, find at a hardware store, the 1.5-2 model, and connect to a garden hose, to pressurize pool systems and pipes, to look for leaks, or used as a water hammer to force clogs out, back the other way. Pushing down on the handle briefly (pump off) can often dislodge the debris, and no gasket replacement is necessary if you are lucky. Additional causes for low water flow in your pump are debris build-up or dirty equipment. We are headquartered in Valley Stream, New York, just outside of New UNK the , . Hello, my motor runs for 20 seconds then stops. Today, I came home to find my pump off after leaving it on this morning. It makes humming sound 1-2 times before starting. I think I have some air leakage on my supply side of my Hayward Super Pump. THANK YOU. 6. PDF | On Jan 1, 2009, Eduardo Keegan and others published Cognitive-behavior therapy. "As for cleaning the pool filters, I do this every couple of days and doesn't help pressure.". Replaced battery on top of pump cover and still nothing??? Whats that part called in case I do break it? It is a Hayward Super Pump 1.5 HP (model #SP2610X15). it does not turn on even though i get 240 volts.My blower is on a different circuit and works properly with 240 volts. Hi Lou, I call that surging, and when a pump does that, and the water level (in the pool) is good, and a stuck skimmer weir is not causing the problem, I would check for an air leak in front of the pump a small void before the impeller that is pulling air in. While the filter pump runs, you can here a drop for a millisecond every roughly 5 mins. I was wondering, I have four returns coming into one pipe to the pump basket. The best way to attack this is with the mantra the problem lies where the power dies. Remove the filter cartridge to see if it continues. Also inspect other wires in the back, look for any pinched wires, or wires touching each other. If clogged, open the pump up, and ream out the impeller vanes with a flexible wire. When you installed the new lateral assy, did the standpipe come all the way up to the top of the tank, and insert neatly into the bottom of the multiport valve? By looking at the return valve, you should be able to see if it is squarely closing off the pool return pipes. Should we already be having problems with it? Hello, We have a circuit board that controls these two motors as well as an LED light. As you found, if the motor sounds just as loud when it is pulled out or removed from the pump housing its usually the bearings, which normally last for up to 10 years, not in this case it seems. I replaced the capacitor last year. Superpump lid gaskets are a square cut gasket that can come out of the groove easily, be sure it is seated properly, and lube it with Teflon pool lube regularly. Inspect the circuit board, blow off with some air, and look closely at the 3 wires for any insects, spiderwebs or corrosion of any type. Heater wont ignite when water temp is above 80 degrees. Verify if your flow switch was installed correctly. Then the others are 2-high speed and 1-low speed wire see the diagram on this page: http://waterheatertimer.org/How-to-wire-Hayward-two-speed-pump.html. Corrosion inside the plug or socket. When we first started both up there were no issues, however now when the heater kicks on the pump starts to make a high pitched noise. No pressure now. In most cases, its going to be #1, just a frozen motor as we say If the shaft spins freely, and it makes a hum or buzz sound for a few seconds before it trips the breaker, probably #4. "width": "611",
If thats not it check the rear of the motor for anything loose (capacitor, centrifugal switch (in the center, on the shaft) or the stationary switch, at 6 oclock, triangular shape. When they fail, they often crack, bulge, leak or smell bad, but not always. Here is the manual: Now, it could also be rust inside the motor, natural when a pump sits for long periods of time, in a non-climate controlled location. Air can also enter through split vac hoses, but since yours is new Third problem could be if the new pump moves much more water than the old pump (not all horsepower pumps are the same 2 different pumps of the same hp, can produce vastly different flow rates. You can patch the fitting usually with pool putty or silicone, but the best repair is to replace the fitting. It looks old and Im thinking about replacing it. Are all connections tight? If you have an electric motor repair shop in town, they may have it in stock, or order it online. Do we need a new pump or can the electrical cord be replaced? Hi, I just had an electrician install a Hayward Super II Energy Efficient Pump 3/4 HP SP3007EECA. Hi Jodi, perhaps the rod is not threaded all the way into the base, or there may be debris under the rod, preventing it from going down fully. the , . 5. low water level or skimmer weir blocking water flow Blower vacuum switch closed when expected open error, If the blower prover switch is closed before blower start-up the control will not start the blower. There isnt a break-in period for these units. Hi Dave, the square gasket for the lid, can sometimes come out of the groove on a Superpump, Id check that first, and make sure the lid is very tight. Turned it off tho clear the skimmer basket.. water level is correct. I calibrated the unit to 3100 ppm. https://twitter.com/inyopoolsFOLLOW us on INSTAGRAM! Im not sure how the filters went bad being winterized, but they were way old. Normally though, it takes more like 15 minutes before the pump is cool enough to turn back on again, at which point you may hear a click, as the overload resets, just a second before the pump turns on again. Just bought a brand-new Hayward pump , starts up in primes great but in about five minutes there was no suction or water flow back to the pool . Thanks. hayward blue essence troubleshooting HELP! Round about 1990 the original AG pump and filter were replaced with used Hayward IG equipment. Did we just ruin our pump?? Hi, my name is Javier I have a 2 HP Hayward two speed pump that is on its second season. Or a loose base part rattling? Replacement of the gasket inside the valve is the fix. i cleaned the filter put the cover back on turned the pump but it doesnt seem to be priming . Upon restart, pump sounds horrible, like pumping rocks. Step 2: Verify the accuracy of the salt readings (2700-3400 pm) with an independent test kit or by taking a water sample to your local pool store for testing. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
I believe I have a bad capacitor. Hello, we have a 2 speed Hayward Tgistar pump it just stopped running, I have east the breakers both at the controller and on the main panel, the pump is hot to the touch and will restart after about two minutes then shutdown again. If the new pump produces greater flow rate than the old pump, it produces high pressure, and poor filtration, and can damage the cartridge. Hi, like some of the other comments, when a pump basket doesnt fully fill with water, doesnt fully catch prime the first thing is to rule out an Air Leak, on the suction side. I get home from work and the pump is running. 240v Input voltage is present. Hi, it could be the filter, and if so, the pressure on the gauge would be high during operation usually. 3. inspect clock and rear of motor for any obvious signs of damage, like watermarks, dirt, insects or something burned or melted I checked the wiring, replaced the breaker, cleaned the pump impeller, motor vents are clean. If no power there, check the timer, if no power there, check the breaker, if no power there Is the main breaker in the house on? Cracked Seal on Case Completely Dry inside. If any of these readings are outside limits, replace motor. I ended up buying a new Hayward pump online however dont want this to happen again. the tubes are sealed at the end by the two seal plates. Any suggestions? Hello, I have a H200 natural gas heater . This is a salt pool not sure if that matters in the question. Thanks! Step 2: Did you properly install your switch? Hi Bill; So you have power coming into your timer or timeclock, but on the out terminals, or the wires that lead to the pump? Yesterday I plugged it in to filter and where the plug goes into the 3 foot heavy duty extension it sparked smoked and created a small flame. Loose wire connections or touching terminal connections cause sparking. I bought same pump and electrician put on old twist lock cord from previous pump. I replaced the entire pump motor and the same thing happened. If its bulged, cracked or otherwise looks damaged, you can assume that it has failed. Tool pump out of storage and hooked up as normal. There are two washers that I have on each side of the spring. Ran fine as long as I didnt turn it off. Hi Jeff, probably that sound is worn bearings (pumps dont have brushes). Should I have it checked or is this normal? Hi Davy! Check for water under the display, or in the control box area. Drain plugs, pump lid, pipe coming into pump, skimmer or main drain valves, low water level, stuck skimmer weir, or the dreaded underground cracks in pipe (rare problem). Tried to backwash. It only blows air but when I take the lid off water comes out and the basket over flows. If power is reaching the box, getting past the transformer, and the fuse is good, it sounds like the main PCB is the issue. Motor was only humming. In my experience, a motor overheating is usually on its last legs what you could do is take it to an electric motor shop in town, and have them run it thru some diagnostics, should not be too expensive, but call first to check. Also check other possible pressure side problems, like a closed or broken exit valve on the filter, or other restrictions further down the line, up to the pool return fittings. Zero on the gauge indicates no water flow, so if not an air leak it could be a clogged line, pump basket or impeller. Fourth, could be a clog or obstruction AFTER the pump, in the filter valve, or in the filter itself. LibriVox is a hope, an experiment, and a question: can the net harness a bunch of volunteers to help bring books in the In a Quirked world where most people have a superpower-like uniqueness to them, His is among the most dangerous. Sorry for the bad news. Hi We just bought a new Hayward Powerflo Matrix pump and filter. Greetings! ), you have it primed full of water? My pool is running, with water flow. Ob, and its just over 4 yrs old. I dont see that code listed. Does this seem odd or excessive? Make sure there is no water in the conduit from the timer to the pump, and breaker to timer. i have a hayward 240 super pump, which have had for about 10 years. Or maybe a clamp? Third time turned off pump same thing happened with humming and eventually kicking in. How to Reset Inspect Cell Light - Hayward POOLSIDE Blog Automatic reset is immediate after the switch closes, Blower vacuum switch open when expected closed error. The pump keeps kicking off every 24 hours and I turn it back on by hitting filter. If not the skimmer being blocked, then its an air leak BEFORE the pump impeller. Does a Hayward super pump wired on 230v have to have a controller?.. Is there something I forgot to do? It could also be a loose switch in the back of the motor. See if the pump motor shaft spins freely, to rule out a motion issue. Please contact me at mbrad39972@hotmail.com. Troubleshooting a Hayward Aqua Rite can be quick and simple. IE9 and older versions are not supported. This time around I purchased the t-3 cell model since my pool is below 15k gallons. You could use a small plug-in pump timer that would allow you to not unplug, just flip the switch to off. Would this make the breaker flip? We have just replaced the seal assembly as suggested by a Hayward rep already. Could also be loose connections on the wires, or insect infestation on the contacts. },
I just purchased a brand new Hayward Super Pump 1.5HP for my pool that is being renovated. Otherwise I would say the switch that changes from low to high may be stuck, from corrosion, insects or breakage. Another piece of information is that the board was replaced back around May of this year as well as the flow sensor. I will be replacing it tomorrow along with the electric socket. Overheating pumps are usually DOA, in my experience, but there may be hope. To reset your average salt level, turn the unit to OFF and then back to AUTO. Students and professors will find thorough, current coverage of all business research topics presented with a balance of theory and practical A Answered on 5/26/2022 by InyoPools Product Specialist Craig C.. Hello J. We have Hayward Perflex filter parts here: https://www.intheswim.com/c/filter-parts?pcode=208&scode=SOCIBLOG. I would call back the electrician, he may have fumbled this while wiring it, such a problem is rare, and could hardly be blamed on the manufacturer, but if your electrician says that its not his fault, have him put in writing on company letterhead, what the defect of the motor is which can help you in getting warranty assistance. Same with other sensors. Below is the troubleshooting guide for Hayward pool heater error codes. "description": "Hayward Pool Heater Troubleshooting Guide - how to step by step approach to determining if the water supply, gas supply, electrical supply or a component of the heater is causing the issue. For a better experience, please enable JavaScript in your browser before proceeding. that sounds like loose wires, or broken wires. Not sure what would cause that?!? This is the round cylinder in the back of the motor, at 9 oclock. It is quite rare that while testing a capacitor, it explodes (small explosion), but it can happen. When I take the lid off the pump hopper I can hear the air releasing, and there cant be any air leaks anywhere as its a new line right from the pump directly into the pool. Is the motor set to accept 220V, and matching what you measure at the motor terminals? It was wired for 230 but only had 115 going into it (we realized this after we had a pool guy come and see it) for a long time. Is that a reason to replace impeller? ), hard to tell until the pump can be tested. Although in low speed, chlorine is not generated so not sure why even run the low speed. Troubleshooting your Hayward salt system Piscines Trvi 8.88K subscribers Subscribe 57K views 3 years ago A salt water system control panel provides all sorts of information. I goes on first, then the spring, then the slightly larger hole washer. Check for possible disruption inside of the flow T. Installation requires 12 inches of straight pipe before the flow switch. If the shaft spins freely, no rust problem. ), it could be a bad breaker, they can fail or become too sensitive with age. We have a variable speed pump for filter and a single stage pump for cleaner. BUT THE BEARINGS. Roger, I call that surging, when the pump catches prime, loses prime, catches again it can be a stuck skimmer weir or a pool noodle blocking water flow into the skimmer. Diagrams, Pool I cant imagine paying someone to take 2 bolts off. info. "image": {
Move switch to center position and adjust dial to a percentage that you think it needs. It need not be a fancy $100 meter, it can be a $10 meter from Radio Shack. If you see any damage, replace your flow switch. I have great circulation, but I the problem is after the pump runs for around a half hour on the filter setting it barely has any force coming out of the jet. Usually OK with a 12 lift, but more than that can be a struggle. 4 New pump 2 years old. John, according to the manual, CEL is the code for Panel not receiving data from control.